Skip to main content

Pre & Post Treatment

Description

Integrated Water Treatment from Source to Distribution

A reverse osmosis system is one part of a complete water treatment process. Pretreatment protects the membranes, while post-treatment, storage, and distribution equipment help ensure the finished water meets the application requirements. MCI WET can supply the complete treatment train, from source-water pumps through final distribution.

A single master controller coordinates pretreatment, reverse osmosis, post-treatment, storage, and distribution as one integrated system. Operators gain one interface for monitoring and control, with single-source accountability for the complete water treatment process.

SPEAK TO AN EXPERT
Write a Review

Pretreatment Systems

  • Source-water and well pumps
  • Multimedia filtration systems
  • Water softening equipment
  • Chemical dosing systems

Post-Treatment Systems

  • pH adjustment systems
  • Remineralization equipment
  • Chlorination and disinfection
  • High-purity water polishing
  • Finished-water storage
  • Distribution pump systems

MCI WET engineers pretreatment and post-treatment equipment as part of complete water treatment systems, from laboratory installations to municipal plants. Each configuration is based on the source-water analysis, required capacity, and finished-water quality.

Proper pretreatment helps protect downstream membranes while reducing cleaning frequency, replacement requirements, and operating cost. Equipment is selected around the water conditions and the facility’s maintenance capabilities.

MCI WET Remote Intelligence provides cloud-based dashboards, operating trends, and early-warning indicators across the treatment process. Operators can monitor critical conditions through one interface and identify changes before production is affected.

Systems are assembled, skid-mounted, pre-plumbed, prewired, and tested at our Dallas facility. Coordinating equipment, controls, integration, and testing under one roof supports consistent quality and single-source accountability.

Pretreatment Protects RO System Performance

MCI WET integrated pretreatment and post-treatment water system

Pretreatment Protects RO System Performance

Effective pretreatment helps prevent membrane fouling, unstable water quality, and avoidable downtime. MCI WET evaluates hardness, iron, chlorine, suspended solids, and other source-water conditions to determine the filtration, softening, and chemical dosing equipment required before reverse osmosis.

MCI WET can engineer the complete treatment train, from source-water pumping through post-treatment, storage, and distribution. Centralized controls coordinate each process, while in-house fabrication, panel manufacturing, integration, and testing provide single-source accountability from design through operation.

Source to Distribution
Centralized System Controls
Skid-Mounted Systems
MCI-Built Control Panels

Designing a Complete Water Treatment Process

Pretreatment protects RO membranes, while post-treatment prepares the finished water for storage, distribution, or process use.

Protecting RO Membrane Performance

Proper pretreatment removes or controls the contaminants that can foul, scale, or damage reverse osmosis membranes. MCI WET evaluates hardness, iron, chlorine, suspended solids, and other source-water conditions to configure the required filtration, softening, and chemical dosing equipment. Designing the system around the actual water analysis helps extend membrane life, reduce cleaning frequency, and support consistent production.

Preparing Water for Its Final Use

Reverse osmosis permeate may require additional conditioning before it enters storage, distribution, or an industrial process. MCI WET can integrate pH adjustment, remineralization, chlorination, high-purity polishing, storage tanks, and distribution pumps. Each post-treatment system is designed around the required finished-water quality, operating pressure, and application standards.

Coordinating the Complete Treatment Train

A centralized master controller integrates pretreatment, reverse osmosis, post-treatment, storage, and distribution as one coordinated system. Operators can monitor equipment status, alarms, and process conditions through one interface. MCI WET provides single-source accountability for system engineering, controls, integration, and long-term support.

Integrated Systems Built Under One Roof

Pretreatment, post-treatment, controls, and system integration are coordinated in Dallas.

MCI WET engineers complete pretreatment and post-treatment packages incorporating pumps, filters, softeners, chemical dosing systems, storage tanks, and distribution equipment. Designing these components as one treatment train helps each stage work with the processes before and after it.

Stainless steel fabrication, integrated piping, PVC assembly, robotic welding and bending, and quality control are coordinated at our Dallas facility. Systems can be skid-mounted, pre-plumbed, and prewired to reduce field assembly and simplify installation.

MCI-built master controls integrate pretreatment, reverse osmosis, post-treatment, storage, and distribution through one interface. UL-listed control and power panels are engineered by MCI, and each complete package is assembled and performance tested before shipment for consistent quality and single-source accountability.

In-House Fabrication
MCI-Built Master Controls
Robotic Welding & Bending
Integrated Quality Control

Scope and Capabilities

  • System Type
    Engineered to order pre-treatment and post-treatment systems
  • Scope of Supply
    Complete, from feed water pumps through distribution pumps
  • Pre-Treatment Equipment
    Feed water and well pumps, media filters, water softeners, chemical feed systems
  • Post-Treatment Equipment
    pH adjustment, remineralization, chlorination, high purity polishing, storage tanks, distribution pumps
  • Controls
    All equipment integrated into a single master system controller
  • System Sizes
    Small laboratory systems through complete municipal systems
  • Design Basis
    Built to an engineer or owner specification, or designed by WET's in-house engineering team
  • Delivery Format
    Packaged and skid mounted, pre-plumbed and pre-wired
  • Fabrication
    In-house stainless fabrication and integrated piping, PVC, robotic welding and bending
  • Control Panel
    Motor Controls Inc., UL listed components
  • Testing
    Factory tested before shipment
  • Monitoring
    Remote Intelligence platform available

PLAN YOUR COMPLETE TREATMENT SYSTEM

Build a Better Water Treatment Process

Share your source-water analysis, required finished-water quality, and capacity goals with MCI WET. Our team can engineer an integrated pretreatment and post-treatment system with centralized controls, storage, pumping, and distribution equipment tailored to your application.

DISCUSS YOUR SYSTEM