Skip to main content

Residential Reverse Osmosis

Description

Heavy-Duty Residential Reverse Osmosis

The MCI WET HDR system provides higher-capacity reverse osmosis water treatment for homes and light commercial applications. Designed for feed water with up to 5,000 ppm total dissolved solids (TDS), it can operate under challenging conditions, including colder source water.

The HDR produces up to 150 gallons per day of filtered water through a high-capacity thin-film composite membrane. It supports household drinking, cooking, coffee, and ice needs, as well as small restaurants, offices, laboratories, and clinics requiring consistent water quality.

Rated production is based on feed water at 77°F, pH 8.0, and 1,000 mg/L TDS. Output varies with water temperature and TDS levels. For feed water above 2,000 ppm TDS, an optional stainless steel pump is available to support system performance.

A stainless steel frame, heavy-duty motor and pump, brass valves, and three pressure gauges provide durable construction and visible operating data. Standard serviceable components simplify maintenance and support a longer system life, with parts and technical assistance available from MCI WET.

SPEAK TO AN EXPERT
Write a Review

HDR Residential RO System Features

  • Plug-and-play automatic operation
  • Thin-film composite RO membrane
  • Integrated reject-flow controller
  • Sediment and KDF/carbon prefiltration
  • Stainless steel frame
  • Heavy-duty motor, pump, and pressure gauges
  • Brass shutoff valve, flush, and sample ports

Available Options

  • Stainless steel pump
  • Handheld TDS meter
  • Level 1 and Level 2 service kits
  • Installation kits
  • 2-, 3-, or 4-gallon storage tank

The MCI WET HDR residential reverse osmosis system is assembled and tested at our Dallas facility. Coordinating manufacturing, testing, parts, and technical support within MCI WET provides consistent quality and a single source for long-term service.

Residential RO for High-TDS Water

Industrial and municipal brackish water reverse osmosis system

RO Built for High-TDS Water

The MCI WET HDR is a heavy-duty residential reverse osmosis system for wells and other feed-water sources with elevated total dissolved solids or colder temperatures. Rated for feed water up to 5,000 ppm TDS, it produces up to 150 gallons per day under rated conditions.

The system is assembled on a stainless steel frame with a heavy-duty motor and pump. Three pressure gauges provide clear operating feedback, while standard serviceable components simplify maintenance and support long-term use.

Every HDR system is assembled and tested at our Dallas facility, with replacement parts and technical support available directly from MCI WET.

Up to 150 GPD
Up to 5,000 ppm TDS
Stainless Steel Frame
Serviceable Components

Choosing a Residential RO System

A residential reverse osmosis system should be evaluated by its rated operating conditions, serviceability, and the support available after installation.

Understand Rated Output

The HDR produces up to 150 GPD at 77°F, pH 8.0, and 1,000 mg/L TDS. Colder water and higher TDS reduce membrane output. For feed water above 2,000 ppm TDS, an optional stainless steel pump is available.

Choose Serviceable Components

The HDR uses individually replaceable filters, membranes, flow controls, valves, and pump components. Three pressure gauges provide visible operating data, helping owners identify performance changes and complete maintenance when needed.

Plan for Long-Term Support

MCI WET assembles and tests every HDR system at our Dallas facility. Replacement parts and technical support are available directly from MCI WET, providing a single source for system maintenance and long-term service.

One Source for Residential RO

Manufacturing and testing are coordinated under one roof.

MCI WET builds HDR residential reverse osmosis systems at our Dallas manufacturing facility, alongside larger industrial and municipal water treatment equipment. Fabrication, assembly, and testing follow the same coordinated quality processes used across our water treatment systems.

Keeping these capabilities in-house supports consistent construction and single-source accountability. Direct relationships with component manufacturers also help MCI WET provide replacement parts and technical support throughout the system’s service life.

Built in Dallas
MCI Assembled & Tested
Integrated Quality Control
Direct Parts & Support

Product Specs

  • Production Capacity
    Up to 150 GPD (568 liters per day)
  • Feed Water TDS
    Up to 5,000 ppm
  • Feed Water Temperature
    Max. 95°F (35°C)
  • Feed Water Turbidity
    1 or less
  • Minimum Feed Pressure
    20 PSI
  • Membrane
    Thin film composite
  • Pre-Filtration
    5 micron cartridge and KDF carbon cartridge
  • Reject Control
    Reject flow controller
  • Frame
    Stainless steel
  • Pump
    Heavy duty motor and pump
  • Instrumentation
    System pressure gauges (3)
  • Valves and Ports
    Brass solenoid on/off valve, brass flush and sample port
  • Operation
    Automatic, plug and play
  • Dimensions
    20" x 13" x 16"
  • Weight
    50 lb.
  • Rating Basis
    77°F (25°C), pH 8.0, 1,000 mg/L TDS
  • Optional Features
    Stainless steel pump, hand held TDS monitor, service kits (Level 1 and 2), installation kits, storage tank (2, 3, or 4 gallon)
  • Note
    Production output is rated at 77°F (25°C), pH 8.0, and 1,000 mg/L TDS. TDS above 1,000 mg/L or temperatures below 77°F will reduce rated production. On feed water above 2,000 ppm, the stainless steel pump option is recommended.

READY TO IMPROVE YOUR WATER?

Find the Right Residential RO System

Share your source-water analysis, daily water needs, temperature, and TDS level. MCI WET will help determine whether the HDR residential reverse osmosis system fits your application and recommend the right options for reliable performance.

START YOUR PROJECT