Skip to main content

Ultra / Micro | Filtration System

Description

Remove Suspended Solids Without Reverse Osmosis

Ultrafiltration and microfiltration remove suspended solids, turbidity, particles, and larger organic matter. Reverse osmosis removes dissolved salts. MCI WET evaluates the source water and treatment goals to determine the right membrane process.

When dissolved-salt levels are acceptable, ultrafiltration or microfiltration may provide the required treatment without reverse osmosis. MCI WET engineers standalone filtration systems and pretreatment systems for downstream membrane processes.

Systems are designed for surface water, seawater, and industrial applications, from demonstration units to large RO pretreatment trains. Each system is engineered for the source water, required capacity, and site conditions.

Systems are assembled, skid-mounted, pre-plumbed, prewired, and tested at our Dallas facility. MCI WET Remote Intelligence adds cloud-based dashboards, operating trends, and early warnings to help operators identify performance changes before production is affected.

SPEAK TO AN EXPERT
Write a Review

Filtration Applications

  • Reverse osmosis pretreatment
  • Municipal drinking water treatment
  • Freshwater and seawater filtration
  • Turbidity and suspended-solids removal

System Capabilities

  • Engineered for the source water, capacity, and treatment goals
  • Pressurized ultrafiltration and microfiltration configurations
  • Skid-mounted, pre-plumbed, and prewired construction
  • Application-specific membranes, components, and controls
  • Demonstration units through large seawater pretreatment trains
  • MCI-built UL-listed control and power panels
  • Optional MCI WET Remote Intelligence monitoring

MCI WET fabricates, assembles, and tests ultrafiltration and microfiltration systems at our Dallas facility. Coordinating fabrication, controls, system integration, and testing under one roof supports consistent quality and single-source accountability.

Choose the Right Membrane Process for Your Application

MCI WET skid-mounted ultrafiltration and microfiltration water treatment system

Choose the Right Membrane Process for Your Application

Ultrafiltration and microfiltration remove suspended solids, turbidity, particles, and larger organic matter. Reverse osmosis removes dissolved salts. When salt levels are acceptable, filtration may provide the required treatment without RO. When both suspended and dissolved contaminants are present, filtration can serve as pretreatment that protects the downstream RO system.

MCI WET evaluates the source-water analysis, required finished-water quality, production capacity, and site conditions before recommending a treatment process. Each filtration system is engineered for the application, with fabrication, controls, system integration, and testing coordinated at our Dallas facility.

Application-Specific Design
Skid-Mounted Systems
MCI-Built Control Panels
UL-Listed Components

Designing for Reliable Membrane Filtration

Source-water conditions, membrane sizing, cleaning requirements, and system integration all influence long-term filtration performance.

Designed for Changing Water Conditions

Surface water and seawater conditions can change by season, weather, and intake location. MCI WET engineers each ultrafiltration or microfiltration system around the source-water analysis, expected operating range, treatment goals, and required capacity. The same application-specific approach supports demonstration units and large reverse osmosis pretreatment trains.

Cleaning and Access Built In

Membrane area, operating flux, cleaning sequences, and component access affect maintenance requirements and system availability. MCI WET considers these factors during design so operators can clean membranes, reach valves, and service critical components without unnecessary disassembly or extended interruptions to water production.

Integrated Before It Reaches Your Site

Systems are assembled, skid-mounted, pre-plumbed, prewired, and tested at our Dallas facility. Integrating piping, membranes, controls, and instrumentation before shipment reduces field assembly and provides single-source accountability for the complete ultrafiltration or microfiltration system.

Complete Filtration Systems Built in Dallas

Fabrication, controls, system integration, and testing are coordinated under one roof.

MCI WET manufactures custom ultrafiltration and microfiltration systems at our Dallas facility. Stainless steel fabrication, integrated piping, PVC work, robotic welding, and robotic bending are coordinated in-house to support consistent construction.

Each filtration system is engineered around the source water, treatment goals, capacity requirements, and site conditions. Keeping fabrication and quality control in-house helps ensure the completed skid reflects the approved design.

UL-listed control and power panels are engineered and built by MCI. Complete systems are assembled and performance tested before shipment, providing single-source accountability from filtration design through long-term support.

In-House Fabrication
MCI-Built UL Panels
Integrated Quality Control
Robotic Welding & Bending

Scope and Capabilities

  • System Type
    Pressurized ultra filtration and micro filtration systems
  • Design Approach
    Engineered to order around the source water, site, and project requirements
  • Applications
    RO pre-treatment Drinking water production Surface water treatment, fresh and seawater Turbidity and suspended solids removal
  • Feed Water
    Fresh surface water and seawater supplies with turbidity, particles, and organic matter
  • Salt Removal
    Not the function of UF/MF. Reverse osmosis is used when dissolved salts must be removed
  • Capacity
    Sized from small demonstration systems through large seawater RO pre-treatment trains
  • Configuration
    Skid mounted, pre-plumbed, and pre-wired
  • Controls
    Current generation controls with system-specific monitoring and early warning visibility
  • Monitoring
    Remote Intelligence platform with dashboard, gauges, and early warnings
  • Control and Power Panels
    UL listed panels built by Motor Controls Inc.
  • Fabrication
    In-house stainless fabrication, integrated piping, PVC work, robotic welding, and robotic bending
  • Factory Testing
    Every system assembled and tested before shipment
  • Installation
    Set and connect field installation instead of a site-built package
  • Support
    Direct manufacturer support with one point of accountability for the full package

NEED A FILTRATION SOLUTION?

Build the Right Filtration System

Share your source-water analysis, treatment goals, capacity requirements, and site conditions with MCI WET. Our engineering team will help determine whether ultrafiltration, microfiltration, or a combined membrane process best fits your application.

DISCUSS YOUR PROJECT